Execution durations in Overview and Testing¶
Execution duration answers how long the work took. It is separate from evidence age, which answers when a report was produced or validated.
Visible fields¶
- Overview's stage checklist and horizontal stage strip show each stage's time.
- The Runs tile shows attempt-wide time separately from run status.
- All six Overview summary tiles include a time field within their default layout.
- Testing's simulation-attempts pane shows timing in each attempt entry, with the same information in attempt details.
Runs and checklist rows show bare durations such as 2m 07s, right-aligned in a
shared duration column beside left-aligned statuses. They omit redundant Time/Elapsed
prefixes; the lifecycle status identifies active work. Standalone summary/detail views
retain descriptive timing labels. Completed measurements freeze; live estimates use
a recorded start. Zero is a valid measured duration. Unknown timing is explicitly
unknown, not zero. Extremely narrow checklist/run rows may omit timing to preserve
readable status. Live display updates use the existing repaint clock, not new provider
requests.
Meaning and availability¶
| Surface | Timed work |
|---|---|
| ASIC stage | Provider-reported terminal occurrence duration; live estimates require a real start and active lifecycle |
| ASIC run | Attempt allocation through outcome, using provider elapsed time; never a sum of stages |
| Synthesis, Placement, Routing summaries | The exact matching stage |
| Timing, Checks summaries | Unknown unless an exact timed stage exists; report age is not analysis runtime |
| Finalization summary | The separate selected finalization receipt's start/end interval; ambiguous receipts remain unknown |
| Simulation attempt | Workbench simulation service start through finish, persisted with the attempt; includes service handling, not simulator CPU time alone |
Completed measurements remain frozen. A retained start alone does not authorize a live estimate. Restart, writer loss or failed observation disables applicable live estimates; recovering an interrupted attempt does not invent an end timestamp. Invalid, negative, nonfinite or future-start durations do not produce misleading elapsed values.
Existing ASIC stage projections can obtain retained stage durations on Refresh. An old registry may already have consumed the start/outcome journal events without retaining their timing: those old run totals/start anchors remain unknown because this implementation does not replay historical events. Old simulation records without timing likewise remain unknown; newly executed attempts persist their timing.
Theme and terminology¶
The Session context's linked keyword uses a semantic Linked role mapped to the
theme's success color plus bold. Built-in schemes supply green success colors.
Host_view.utility_attrs controls this mapping and Host_view.Role.palette supplies
scheme colors. Custom colors currently require OCaml changes; there is no arbitrary
user-theme configuration file. Built-in schemes remain selectable through Appearance.
An inspector is a detailed report view opened from a tile, such as timing paths, clocks or artifact details. Space c x closes the focused detail view.
Compatibility and verification¶
The optional X-Workbench-Execution-Timing: 1 HTTP request header independently
negotiates timing fields on ASIC and simulation responses. Without that exact opt-in,
the daemon omits timing fields at serialization so strict old readers remain compatible.
Evidence-metadata negotiation alone does not enable execution timing. Old records and
old-server responses decode with missing timing as unknown.
Full combined build, tests and lint passed with -j4. Focused tests cover provider
timing validation, lifecycle/restart retention, transport compatibility, visible default
tile layouts, exact stage/run selection, frozen and live values, and narrow clipping.
Owner feedback on 2026-10-21 accepts Testing behavior and authorizes closing the
non-signoff-dependent work in this set. Simulation-attempt duration presentation is
therefore accepted. Clock/timing report review is blocked by the failed signoff run;
no successful signoff-report validation is implied by that closure.
See Timing workspace settings for configurable background loading and inspection detail caching.