Connect to Silver from Cobalt

Start Cobalt with the endpoint of an already-running Silver daemon and the canonical absolute Silver project root (pwd -P in the project):

cobalt --silver-endpoint http://127.0.0.1:30900 \
  --silver-project /work/my-project path/to/file

--silver-endpoint and --silver-project are required together. No attempt is needed. Add --silver-run ATTEMPT_ID to put that attempt's status above the test catalog; use the attempt ID, not a job ID. The file or directory being edited never selects or changes the Silver binding.

From ordinary standalone Cobalt, open Silver: Discover/Connect… in the command palette (Space c c, query silver connect). Choose a listed project with Tab and press Enter. The share determines the project; it need not match the editor's startup root. For a manual connection, type a loopback HTTP URL instead: this opens the editor's startup root, not the current buffer's directory. Use the paired CLI flags above to enter a different root manually. Neither path starts a daemon. A failed connection leaves the previous binding unchanged.

On the Silver side, open Share with Cobalt… for the current project and confirm. Cobalt lists live offers only, showing the project name and root, mode (embedded or attached), and a short offer ID to distinguish Silver windows. Stopping sharing removes that offer for new connections; existing Cobalt connections and Silver jobs continue. The overview shows the verified project and retained attempts; use r to refresh them. Silver's native daemon.sexp is a daemon address, not a project share.

Silver: Overview starts in the bottom band, with focus still in the editor. Use Space v S to hide or show it (Toggle Silver: Overview in the command palette), or Space v U to focus it. In the tile, j/k move, r refreshes the current view, and Escape returns to the editor. To see long scope values, focus the tile and use Space s t to move it to a full-width tab. In Zen, Space v z restores the workspace band. To quit, return to the editor and press Space q.

Labels and values stay aligned as you scroll. Lifecycle and outcome keywords use theme colors; identifiers and paths remain ordinary text.

Show the Silver workspace

Open the command palette (Space c c) and choose Layout: Silver to show Status and put Silver: Overview, Silver: Stage Checklist, and Silver: Flow Runner in the bottom band. Choose Layout: Default to restore the default workspace; of the Silver tiles, only Silver: Overview remains visible. Both presets leave Zen and return focus to the editor. Toggling Zen itself preserves the current layout. The presets do not change your Silver binding, start a daemon or launch a run. If no project is connected, the Silver tiles explain what is unavailable. Use Silver: Discover/Connect… separately to establish a binding. In a build without the Silver adapter, Layout: Silver reports that it is unavailable and leaves your layout unchanged.

Quick launch a test

In the project catalog, R runs the selected suite or variant. A suite runs all its cases. Enter opens settings; Tab moves between fields, Ctrl-U clears a field, Enter applies, and Escape cancels. Applying never starts a run.

From code, open the command palette (Space c c) and type exactly test. It offers the configured target (--silver-test-default SUITE[/VARIANT]) or the last acknowledged target for that project. With neither, it opens a picker. The launch uses the settings for that exact target; suite and variant overrides are independent and remain available when the tile is hidden. Silver runs saved project inputs, not unsaved editor buffers.

An accepted launch records its attempt and job IDs in History (Space v M; use Space s t or Enter to see a long entry). Delivery unconfirmed means Silver may already be running the test; check Silver before trying again. Cobalt never resubmits automatically. When Silver reports a stale catalog, choose the target again from the refreshed catalog.

Launch through a stage

Open Silver: Stage Checklist in the command palette (Space c c). Use j/k to select a stage and R to run the active flow through it. Escape returns to the editor; Toggle Silver: Stage Checklist hides it. The checklist follows ASIC execution for the verified project and active flow selection, separately from the Testing attempt shown by --silver-run. Use [ and ] to pin an older or newer matching retained ASIC run, or L to resume following latest. A pin is local to this project, chip/variant, flow, and profile; changing any of those clears the pin. Hiding the checklist pauses observation, not Silver execution.

Statuses update while the checklist is visible, without a keypress; r requests a progress refresh without changing launch settings. Reported stages appear in Silver's order, followed by additional launch destinations. Muted rows have no confirmed progress: a requested endpoint does not prove that it or its prerequisites ran. The cts row is clock tree synthesis. When latest is ambiguous, [ can choose from the available dated matches.

› marks the selected row. What the observed run did is separate from what R can launch now: evidence-only stages cannot be launched, and an allowed fresh launch does not need a prior run. The observed run never supplies launch settings.

Exact palette queries synth, timing, and routing resolve their named stages, independent of the checklist selection, even while the checklist is hidden. An unavailable exact query reports why and launches nothing. The aliases use Silver's declared mappings, not inferred endpoint names.

Opening or browsing the checklist starts no runs. A stage launch preserves applicable settings, uses saved project inputs, and leaves any watched attempt unchanged. The flow selector supplies the flow/profile and any applied assignments; the checklist changes only the endpoint. An acknowledgement includes the accepted run or workflow identity; an unconfirmed acknowledgement is not retried. A stale selection must be selected again. See companion flow capability requirements.

Kick off a named flow

Open Silver: Flow Runner from the command palette (Space c c), or type the exact query flow. The alias shows and focuses the compact selector even if hidden or in Zen, and stays on it if already focused. If there is no room in the bottom band, the same selector opens as a tab. The alias neither switches flows nor starts a run. j/k immediately makes the highlighted flow active using Silver's declared profile and defaults (or previously applied overrides for that flow). Selecting a flow starts no jobs and needs no Enter. Open the stage checklist (st in the palette) and press R to run through the highlighted stage. Toggle Silver: Flow Runner hides the selector and returns focus to the editor; Escape returns without hiding it.

For explicit inputs and plan review, open the separate Silver: Flow Review tab. Pick a flow and press Enter to edit; Tab switches fields, Ctrl-U clears a field, Enter applies, and Escape cancels. Leave an unspecified parameter blank to use Silver's settings. Press p for a preview, check the resolved target, flow, profile, endpoint and parameters, then press K to submit that exact preview. Applying and previewing start no physical run and never save open buffers. Toggle Silver: Flow Review closes the review tab. A changed catalog invalidates the preview; if delivery is unconfirmed, check Silver before trying again. Cobalt does not retry.

Watch an attempt

  • Fresh: Silver returned the status of that exact attempt.
  • Stale: the last matching status is retained while Cobalt retries.
  • Unavailable: Cobalt has no matching status for the current observation.

Lifecycle and Outcome are separate; an Unknown outcome does not by itself mean the run is pending.

Hiding the tile abandons attempt observation, not the project binding, settings, or pending launch acknowledgements. Reopening starts a fresh observation of the same attempt. Quitting stops local work but does not cancel Silver runs. Cobalt and Silver have independent focus and scroll state.

The adapter is selected at build time; a build without silver_overview/ still edits normally. Those builds reject an explicit Silver binding.